FIRE PROTECTION WORKS

Below are the fire protection price for equipment and materials that we usually used on the project. The cost indicated are in Philippine Peso with vat exclusive. Prices for the pipe used in fire protection are indicated in STEEL PIPES PRICELIST.

Fire protection systems are critical for building safety. Whether you’re planning a commercial facility, residential building, or industrial warehouse, installing the right fire protection materials ensures compliance with fire codes and saves lives. Therefore, staying informed about the latest fire protection system prices in the Philippines helps contractors, engineers, and property owners make better project decisions.


What Is a Fire Protection System?

Fire protection systems include a wide range of mechanical components designed to detect, control, and suppress fire. These systems typically feature:

  • Sprinkler heads and valves
  • Black iron and galvanized pipes
  • Alarm check valves and flow switches
  • Fittings, hangers, and supports
  • Pressure gauges and test drains

Together, these components form an integrated system that automatically responds during emergencies.

In addition, most modern buildings are required by law to include automatic sprinkler systems as part of their fire safety compliance.


Common Applications in Construction

Engineers and builders frequently install fire protection systems in:

  • 🏢 High-rise buildings
  • 🏭 Factories and warehouses
  • 🏬 Commercial malls and retail outlets
  • 🏠 Condominiums and residential buildings
  • 🏫 Schools, hospitals, and government facilities

Furthermore, many local building codes now require fire protection for parking structures, server rooms, and kitchens, especially in mixed-use developments.


Fire Protection System Components

Fire systems involve many specialized materials and parts. Some of the most commonly used components include:

  • Schedule 40 black iron pipes – ideal for sprinkler risers and mains
  • Grooved and threaded fittings – allow faster assembly and disassembly
  • Sprinkler heads (upright, pendant, sidewall) – discharge water during fire events
  • Alarm valves, check valves, and pressure regulators – control water flow and direction
  • Flexible sprinkler hoses and couplings – simplify ceiling-level installations

In addition, fire systems may integrate with alarm panels, flow switches, and tamper switches to alert building occupants and first responders.


What Affects Fire Protection System Prices?

Several key factors influence the cost of fire protection materials:

  • Pipe size and wall thickness
  • Brand and product certification (e.g., UL/FM listed)
  • Type of sprinkler heads or valves
  • Imported vs. locally sourced materials
  • Volume of purchase (retail vs. wholesale)
  • Supplier location and delivery fees

As a result, prices may vary significantly between projects—especially if custom configurations or specialized equipment are required.


For pipe installation man hours, please check the link: PIPE INSTALLATION MAN HOURS

For other pipe material price list, check the reference below:
– Stainless Steel Pipes, please check the link: SS PIPE PRICE LIST
– PPR Pipes, please check the link: PPR PIPES PRICE LIST
– uPVC Pipes, please check the link: uPVC PIPES PRICE LIST
– Black Iron Pipes, please check the link: BI PIPES  PRICE LIST


FIRE PROTECTION PRICE LIST

Below is the updated price list for common fire protection materials such as black iron pipes, sprinkler heads, grooved fittings, valves, and accessories. These are typical materials used in most wet-pipe sprinkler systems in the Philippines.

SPRINKLER SYSTEM PRICE LIST
ITEMDESCRIPTIONQUANTITYUNIT PRICE (IN PHP)
1.0Fire Pump, Horizontal Split Case Fire Pump, UL/FM approved, 200Hp Motor, 1000 GPM @ 200 PSI, with UL/FM Pump Controller 1 set 3,599,876
2.0Jockey Pump, Vertical In-Line multi-stage centrifugal pump, 40 GPM @ 200 PSI, 7.5Hp, with pump controller 1 set 568,326
3.0Upright Sprinkler Heads, 1/2″orif.x 1/2″ NPT 1 pc 632
4.0Spare Sprinkler Cabinet, Capacity = 12pcs 1 set 12,640
5.0Standard Wrench, 1/2″NPT 1 pc 1,896
6.0Indoor Fire Hose Cabinet, UL/FM Approved,
– Angle hose valve, 1 1/2″
– Fire Hose Rack
– Fire Hose single Jacket with couplings and straight/fog nozzle, 1 1/2″ x 100ft
– ABC dry powder portable fire extinguisher
– Universal Spanner
1 set 25,280
7.0Outdoor Fire Hose Cabinet, UL/FM Approved,
– Angle hose valve, 1 1/2″
– Fire Hose Rack
– Fire Hose single Jacket with couplings and straight/fog nozzle, 1 1/2″ x 100ft
– ABC dry powder portable fire extinguisher
– Universal Spanner
1 set 25,279
8.0Alarm Valve, 6″dia.,Flange, Vertical c/w, water motor alarm assembly, variable pressure trim, retarfing chamber 1 set 107,406
SPRINKLER SYSTEM PRICE LIST
ITEMDESCRIPTIONQUANTITYUNIT PRICE (IN PHP)
9.0Floor Control Valve Assembly
9.1Flow Switch, 6″ Diameter Size 1 pc 29,656
9.2Pressure Gauge, 100mm diameter dial 1 pc 7,577
9.3Test valve 32 mm Diameter 1 pc 3,158
9.4Sight Test 32 mm Diameter 1 pc 1,264
9.5Sectional drain Valve 50 mm Dia 1 pc 3,162

SENSING LINE

SPRINKLER SYSTEM PRICE LIST
ITEMDESCRIPTIONQUANTITYUNIT PRICE (IN PHP)
10.0Sensing Line
10.1Ø90 Pressure gauge oil filled 1 pc 9,479
10.2Globe Valve, 1/2″ dia. 1 pc 3,160
10.3Tee w/ Ø8 Plug 1 pc 1,264
10.4Check Valve, 1/2″ diameter w/ 2mm orifice in clapper 1 pc 4,421
10.5Pressure gauge 1 pc 7,586
10.6Sight glass & Inspector Test Valve 1 pc 3,202
10.7Drain Ball Valve, 50mm Diameter 1 pc 3,160

VALVES AND ACCESSORIES

SPRINKLER SYSTEM PRICE LIST
ITEMDESCRIPTIONQUANTITYUNIT PRICE (IN PHP)
11.0Fire Deparment Connection
Four way, 6″x 2 1/2″ x 2 1/2″ x 2 1/2″ x 2 1/2″
c/w 2 1/2 Pin lug plugs & brass escutcheon plate
1 set 44,216
12.0Flow Meter, 6″ Diameter 1 pc 94,770
13.0Landing Hose Gate Valve, 2 1/2″ with non-rising stem w/ cap & Chain, Straight 1 set 15,802
14.0Valves & Accessories:
14.1Vortex Plate, 8″ dia. c/w strainer 1 pc 44,228
14.2Flexible Coupling, 6″ diameter, grooved 1 pc 1,895
14.3Flexible Coupling, 2″ diameter, grooved 1 pc 632
14.4Victaulic Coupling, 8″ diameter 1 pc 2,526
14.5Victaulic Coupling, 2″ diameter 1 pc 947
14.6Butterfly Valve, 6″,wafer type connection 1 pc 44,255
14.7Pressure Relief Valve, 6″ diameter 1 pc 315,992
14.8Pressure Relief Valve, 1 1/2″ diameter 1 pc 63,161
14.9Swing Check valve 6”, Flange type connection 1 pc 63,204
15Swing Check valve 2”, Threaded type connection 1 pc 18,941
15.1OS & Y Gate Valves, 8″dia., Flange type conneciton 1 pc 82,136
15.2OS & Y Gate Valves, 6″dia., Flange type connection 1 pc 56,821
15.3OS & Y Gate Valves, 2″dia., threaded type connection 1 pc 38,516
15.5Fire Hose Valve 2 1/2″ complete with Hose and Chain 1 pc 9,476

In addition, many suppliers offer volume discounts or bundled packages for large-scale developments or long-term contractor partnerships.


Installation Tips and Best Practices

To ensure proper installation, keep the following tips in mind:

  • Follow NFPA or local fire code standards
  • Use UL/FM-listed materials for critical systems
  • Test for pressure and flow rates before commissioning
  • Install brackets and hangers at appropriate intervals
  • Maintain clear access to valves and drain points

Furthermore, schedule regular system inspections and maintenance to ensure your fire protection setup remains effective over time.


Conclusion

In summary, fire protection systems form a vital line of defense against life-threatening emergencies. Choosing the right materials—at the right price—allows you to meet safety requirements without exceeding your project budget.

Therefore, keeping this price list up to date helps you plan smarter, quote more accurately, and build safer.


HELP US

We want to improve this website so we need your help. Please send us your recommendations, suggestion, and request. Click this for the SUGGESTION FORM PAGE.

Dont forget to hit Like and Share if this blog helped you.

FOLLOW US!

Please like and follow our facebook page for social media updates.

https://www.facebook.com/theprojectestimate

Please check other post for more reference:

THEPROJECTESTIMATE.COM HOMEPAGE

CONSTRUCTION LABOR COST

EQUIPMENT RENTAL COST