Below are the fire protection price for equipment and materials that we usually used on the project. The cost indicated are in Philippine Peso with vat exclusive. Prices for the pipe used in fire protection are indicated in STEEL PIPES PRICELIST.
Fire protection systems are critical for building safety. Whether you’re planning a commercial facility, residential building, or industrial warehouse, installing the right fire protection materials ensures compliance with fire codes and saves lives. Therefore, staying informed about the latest fire protection system prices in the Philippines helps contractors, engineers, and property owners make better project decisions.
What Is a Fire Protection System?
Fire protection systems include a wide range of mechanical components designed to detect, control, and suppress fire. These systems typically feature:
- Sprinkler heads and valves
- Black iron and galvanized pipes
- Alarm check valves and flow switches
- Fittings, hangers, and supports
- Pressure gauges and test drains
Together, these components form an integrated system that automatically responds during emergencies.
In addition, most modern buildings are required by law to include automatic sprinkler systems as part of their fire safety compliance.
Common Applications in Construction
Engineers and builders frequently install fire protection systems in:
- 🏢 High-rise buildings
- 🏭 Factories and warehouses
- 🏬 Commercial malls and retail outlets
- 🏠 Condominiums and residential buildings
- 🏫 Schools, hospitals, and government facilities
Furthermore, many local building codes now require fire protection for parking structures, server rooms, and kitchens, especially in mixed-use developments.
Fire Protection System Components
Fire systems involve many specialized materials and parts. Some of the most commonly used components include:
- Schedule 40 black iron pipes – ideal for sprinkler risers and mains
- Grooved and threaded fittings – allow faster assembly and disassembly
- Sprinkler heads (upright, pendant, sidewall) – discharge water during fire events
- Alarm valves, check valves, and pressure regulators – control water flow and direction
- Flexible sprinkler hoses and couplings – simplify ceiling-level installations
In addition, fire systems may integrate with alarm panels, flow switches, and tamper switches to alert building occupants and first responders.
What Affects Fire Protection System Prices?
Several key factors influence the cost of fire protection materials:
- Pipe size and wall thickness
- Brand and product certification (e.g., UL/FM listed)
- Type of sprinkler heads or valves
- Imported vs. locally sourced materials
- Volume of purchase (retail vs. wholesale)
- Supplier location and delivery fees
As a result, prices may vary significantly between projects—especially if custom configurations or specialized equipment are required.
For pipe installation man hours, please check the link: PIPE INSTALLATION MAN HOURS
For other pipe material price list, check the reference below:
– Stainless Steel Pipes, please check the link: SS PIPE PRICE LIST
– PPR Pipes, please check the link: PPR PIPES PRICE LIST
– uPVC Pipes, please check the link: uPVC PIPES PRICE LIST
– Black Iron Pipes, please check the link: BI PIPES PRICE LIST
FIRE PROTECTION PRICE LIST
Below is the updated price list for common fire protection materials such as black iron pipes, sprinkler heads, grooved fittings, valves, and accessories. These are typical materials used in most wet-pipe sprinkler systems in the Philippines.
| SPRINKLER SYSTEM PRICE LIST | |||||
|---|---|---|---|---|---|
| ITEM | DESCRIPTION | QUANTITY | UNIT | PRICE (IN PHP) | |
| 1.0 | Fire Pump, Horizontal Split Case Fire Pump, UL/FM approved, 200Hp Motor, 1000 GPM @ 200 PSI, with UL/FM Pump Controller | 1 | set | 3,599,876 | |
| 2.0 | Jockey Pump, Vertical In-Line multi-stage centrifugal pump, 40 GPM @ 200 PSI, 7.5Hp, with pump controller | 1 | set | 568,326 | |
| 3.0 | Upright Sprinkler Heads, 1/2″orif.x 1/2″ NPT | 1 | pc | 632 | |
| 4.0 | Spare Sprinkler Cabinet, Capacity = 12pcs | 1 | set | 12,640 | |
| 5.0 | Standard Wrench, 1/2″NPT | 1 | pc | 1,896 | |
| 6.0 | Indoor Fire Hose Cabinet, UL/FM Approved, – Angle hose valve, 1 1/2″ – Fire Hose Rack – Fire Hose single Jacket with couplings and straight/fog nozzle, 1 1/2″ x 100ft – ABC dry powder portable fire extinguisher – Universal Spanner | 1 | set | 25,280 | |
| 7.0 | Outdoor Fire Hose Cabinet, UL/FM Approved, – Angle hose valve, 1 1/2″ – Fire Hose Rack – Fire Hose single Jacket with couplings and straight/fog nozzle, 1 1/2″ x 100ft – ABC dry powder portable fire extinguisher – Universal Spanner | 1 | set | 25,279 | |
| 8.0 | Alarm Valve, 6″dia.,Flange, Vertical c/w, water motor alarm assembly, variable pressure trim, retarfing chamber | 1 | set | 107,406 | |
| SPRINKLER SYSTEM PRICE LIST | |||||
|---|---|---|---|---|---|
| ITEM | DESCRIPTION | QUANTITY | UNIT | PRICE (IN PHP) | |
| 9.0 | Floor Control Valve Assembly | ||||
| 9.1 | Flow Switch, 6″ Diameter Size | 1 | pc | 29,656 | |
| 9.2 | Pressure Gauge, 100mm diameter dial | 1 | pc | 7,577 | |
| 9.3 | Test valve 32 mm Diameter | 1 | pc | 3,158 | |
| 9.4 | Sight Test 32 mm Diameter | 1 | pc | 1,264 | |
| 9.5 | Sectional drain Valve 50 mm Dia | 1 | pc | 3,162 | |
SENSING LINE
| SPRINKLER SYSTEM PRICE LIST | |||||
|---|---|---|---|---|---|
| ITEM | DESCRIPTION | QUANTITY | UNIT | PRICE (IN PHP) | |
| 10.0 | Sensing Line | ||||
| 10.1 | Ø90 Pressure gauge oil filled | 1 | pc | 9,479 | |
| 10.2 | Globe Valve, 1/2″ dia. | 1 | pc | 3,160 | |
| 10.3 | Tee w/ Ø8 Plug | 1 | pc | 1,264 | |
| 10.4 | Check Valve, 1/2″ diameter w/ 2mm orifice in clapper | 1 | pc | 4,421 | |
| 10.5 | Pressure gauge | 1 | pc | 7,586 | |
| 10.6 | Sight glass & Inspector Test Valve | 1 | pc | 3,202 | |
| 10.7 | Drain Ball Valve, 50mm Diameter | 1 | pc | 3,160 | |
VALVES AND ACCESSORIES
| SPRINKLER SYSTEM PRICE LIST | |||||
|---|---|---|---|---|---|
| ITEM | DESCRIPTION | QUANTITY | UNIT | PRICE (IN PHP) | |
| 11.0 | Fire Deparment Connection Four way, 6″x 2 1/2″ x 2 1/2″ x 2 1/2″ x 2 1/2″ c/w 2 1/2 Pin lug plugs & brass escutcheon plate | 1 | set | 44,216 | |
| 12.0 | Flow Meter, 6″ Diameter | 1 | pc | 94,770 | |
| 13.0 | Landing Hose Gate Valve, 2 1/2″ with non-rising stem w/ cap & Chain, Straight | 1 | set | 15,802 | |
| 14.0 | Valves & Accessories: | ||||
| 14.1 | Vortex Plate, 8″ dia. c/w strainer | 1 | pc | 44,228 | |
| 14.2 | Flexible Coupling, 6″ diameter, grooved | 1 | pc | 1,895 | |
| 14.3 | Flexible Coupling, 2″ diameter, grooved | 1 | pc | 632 | |
| 14.4 | Victaulic Coupling, 8″ diameter | 1 | pc | 2,526 | |
| 14.5 | Victaulic Coupling, 2″ diameter | 1 | pc | 947 | |
| 14.6 | Butterfly Valve, 6″,wafer type connection | 1 | pc | 44,255 | |
| 14.7 | Pressure Relief Valve, 6″ diameter | 1 | pc | 315,992 | |
| 14.8 | Pressure Relief Valve, 1 1/2″ diameter | 1 | pc | 63,161 | |
| 14.9 | Swing Check valve 6”, Flange type connection | 1 | pc | 63,204 | |
| 15 | Swing Check valve 2”, Threaded type connection | 1 | pc | 18,941 | |
| 15.1 | OS & Y Gate Valves, 8″dia., Flange type conneciton | 1 | pc | 82,136 | |
| 15.2 | OS & Y Gate Valves, 6″dia., Flange type connection | 1 | pc | 56,821 | |
| 15.3 | OS & Y Gate Valves, 2″dia., threaded type connection | 1 | pc | 38,516 | |
| 15.5 | Fire Hose Valve 2 1/2″ complete with Hose and Chain | 1 | pc | 9,476 | |
In addition, many suppliers offer volume discounts or bundled packages for large-scale developments or long-term contractor partnerships.
Installation Tips and Best Practices
To ensure proper installation, keep the following tips in mind:
- Follow NFPA or local fire code standards
- Use UL/FM-listed materials for critical systems
- Test for pressure and flow rates before commissioning
- Install brackets and hangers at appropriate intervals
- Maintain clear access to valves and drain points
Furthermore, schedule regular system inspections and maintenance to ensure your fire protection setup remains effective over time.
Conclusion
In summary, fire protection systems form a vital line of defense against life-threatening emergencies. Choosing the right materials—at the right price—allows you to meet safety requirements without exceeding your project budget.
Therefore, keeping this price list up to date helps you plan smarter, quote more accurately, and build safer.
HELP US
We want to improve this website so we need your help. Please send us your recommendations, suggestion, and request. Click this for the SUGGESTION FORM PAGE.
Dont forget to hit Like and Share if this blog helped you.
FOLLOW US!
Please like and follow our facebook page for social media updates.
https://www.facebook.com/theprojectestimate
Please check other post for more reference: